Insulation Calculator

R-value and U-value from a thickness and a conductivity, plus the thickness that meets a target R.

Privacy First
0 Runs
Updated 2026-11-21
Runs in your browser
No sign-up, no upload

What the insulation calculator does

It evaluates R = d / λ for one homogeneous layer, where d is the thickness in metres and λ the material's thermal conductivity in W/(m·K). 100 mm of a material at 0.035 W/(m·K) is R 2.8571 m²K/W, and U = 1 / R is 0.35 W/(m²K).

The imperial R is the metric value times 5.678263, so the same layer reads 16.2236 ft²·°F·h/Btu, which is the number a US product label would show.

Because the same relation runs both ways, a Target R you type returns the thickness that meets it: R 3.5 of the same material needs 122.5 mm. That is the thickness of the same material, not a different product.

The layer is one homogeneous material in steady state. Framing bridges, surface films and moisture are not included, and λ is the value you supply rather than this page's guess. A thickness of zero or below is refused, a conductivity outside 0 to 1 is refused as not an insulation material, and a target R of zero or below is refused.

Figures print to up to four decimal places with trailing zeros trimmed.

How to use it

Set Thickness in millimetres and Conductivity to the material's declared λ.

Optionally set Target R to see the thickness that reaches it, then press Run. The result prints R, U, the imperial R and, when asked, the target thickness.

Worked example

Input with the defaults (100 mm, 0.035 W/(m·K), target R 3.5):

R-value:       2.8571 m²K/W (d ÷ λ)
U-value:       0.35 W/(m²K) (1 ÷ R)
Imperial R:    16.2236 ft²·°F·h/Btu (metric × 5.678263)
For R 3.5:     122.5 mm (R × λ; the same material, thicker)

Why it runs in your browser

The divisions run in this tab. The material's values are never uploaded and nothing is stored.

The page evaluates the R-value of one homogeneous layer, R = d / λ, from the thickness in metres and the material's thermal conductivity in W/(m·K). It also prints the U-value, 1 / R, and the imperial R a US product label would show.

A hundred millimetres of a material at 0.035 W/(m·K) is R 2.8571 m²K/W and U 0.35 W/(m²K). The imperial figure is the metric one times 5.678263, so the same layer reads 16.2236.

The same relation runs the other way: type a target R and the page returns the thickness of that material which meets it. Because it is one layer in steady state, framing bridges and surface films are named as excluded.

What R and U measure

An R-value is a resistance: how hard it is for heat to cross a layer. A higher R is better insulation, and it grows with thickness and shrinks with conductivity. A U-value is the conductance, 1 / R, so a higher U is worse — it is the number a window is often quoted in.

Because they are reciprocals, printing both is not two answers. It is one answer in the two conventions, and the reciprocal also shows why R and U move in opposite directions when the layer changes.

One layer, steady state, no bridges

A real wall is a stack of layers in series and a frame in parallel with the insulation. The R-values of layers add, but the frame short-circuits part of the area, so a wall's whole-assembly R is lower than the insulation's alone. This page computes one layer.

Surface films on both faces add resistance too, and moisture can change a material's conductivity outright. The page takes the conductivity you supply, applies one division, and states that the assembly effects are not included.

How to use Insulation Calculator

Set Thickness in millimetres and Conductivity to the material's declared λ in W/(m·K).

Set Target R if you want the thickness that reaches it; leave it blank to see only the layer you have.

Press Run. The result prints R, U, the imperial R and, when a target is given, the thickness of the same material that meets it.

What to Expect

Best for

  • An R-value from a thickness and a declared conductivity
  • The thickness of a material that reaches a target R
  • Converting a metric R to the imperial figure on a label

Not ideal for

  • A whole wall assembly with framing and surface films
  • A material whose conductivity changes with moisture or temperature

What this tool keeps

  • The thickness, conductivity and target you typed
  • R, U and the imperial R from the same division

What may need cleanup

  • A thickness in inches, which has to be converted to millimetres
  • A conductivity quoted in Btu·in/(h·ft²·°F), which has to be converted

Common errors

  • Using the assembly R where the material's own R was meant
  • Leaving the target R filled in while reading the current layer's R

Example use cases

  • Checking a batt's stated R against its thickness
  • Sizing a layer for a target R
  • Reading a US label's imperial R from a metric figure

Sample input

100 mm at 0.035 W/(m·K), with a target R of 3.5.

Sample output

R 2.8571 m²K/W, U 0.35 W/(m²K), and 122.5 mm for R 3.5.

Who this is for

  • Builders comparing insulation thicknesses
  • Anyone checking an R-value on a datasheet

Frequently asked questions

Why do R and U move in opposite directions?

They are reciprocals. R measures resistance, so a thicker layer raises it; U measures conductance, so the same layer lowers it. U = 1 / R and the page prints both.

Does this include the studs or the plasterboard?

No. It is one homogeneous layer. A real wall adds layers in series and a frame in parallel, and the frame lowers the assembly R below the insulation's own.

What is the imperial R?

The same resistance in ft²·°F·h/Btu, which is what a US product label shows. It is the metric R multiplied by 5.678263, so no new calculation is involved.

Why is a conductivity above 1 refused?

One W/(m·K) is already a poor insulator — closer to a dense solid than to an insulation material. A value above it is usually a unit mistake, so the page refuses it rather than printing a misleading R.