Viscosity Converter screenshot

Viscosity Converter

Convert between centipoise, poise, pascal-seconds, centistokes and stokes at the density you give.

Privacy First
0 Runs
Updated 2026-11-06
No upload
Instant
No signup

Dynamic and kinematic viscosity

The page converts a viscosity across the dynamic units and the kinematic units, and between the two families through the density you supply. One pascal-second is 1000 centipoise and 10 poise; one stoke is 100 centistokes and 10⁻⁴ m²/s; and µ = ν × ρ joins them, so 5 cP at 1 g/cm³ prints as 0.005 Pa·s and 5 cSt.

Dynamic viscosity resists flow and kinematic viscosity is that divided by density, so crossing between them is only correct at one temperature and one density; the page takes the density as an input and prints the figure it used rather than assuming 1. A density of zero would divide, so it is refused, as is a negative viscosity, and an unrecognised unit name is refused rather than defaulted.

The arithmetic runs in this tab from the values you type. Nothing is uploaded, no fluid table is consulted, and the same input prints the same readings after a reload.

The page converts a viscosity across the dynamic units and the kinematic units, and crosses between the two families through the density you supply: one pascal-second is 1000 centipoise and 10 poise, one stoke is 100 centistokes and 10⁻⁴ m²/s, and µ = ν × ρ joins them. Five centipoise at 1 g/cm³ prints as 0.005 Pa·s and 5 cSt. Every reading is printed with the density it used.

Centipoise to poise to stokes, at the density you type.

How to use it

Type a viscosity, choose one of cP, P, Pa·s, cSt or St, enter the density in g/cm³ and press Run. The dynamic reading and the kinematic reading are printed together with the density applied.

What it will not do

Dynamic and kinematic viscosity are different quantities and only meet at one density and one temperature, so the page takes the density as an input rather than assuming 1. A density of zero would divide and is refused, as is a negative viscosity; an unknown unit name is refused rather than defaulted.

What to Expect

Best for

  • Comparing a fluid datasheet written in centipoise with one written in centistokes.

What this tool keeps

  • The conversions run in this tab from the values you typed; nothing is uploaded and no fluid table is consulted.

Sample input

5 cP at 1 g/cm³

Sample output

0.005 Pa·s (5 cP, 0.05 P) 0.05 St (5 cSt) at 1 g/cm³ 1 Pa·s = 1000 cP; 1 St = 100 cSt = 1e-4 m²/s; µ = ν × ρ.

Frequently asked questions

How do I use the viscosity converter?

Fill in the fields above and press Run. Type a viscosity, choose one of cP, P, Pa·s, cSt or St, enter the density in g/cm³ and press Run. The dynamic reading and the kinematic reading are printed together with the density applied.

Is my input uploaded?

No. Every figure is computed in this tab with JavaScript. Nothing is posted to a server, nothing is stored, and the page keeps working offline once it has loaded.

What are the limits?

The viscosity must be zero or above, the density must be above 0 g/cm³ and the unit must be one of cP, P, Pa·s, cSt or St; anything else is refused.

Developer program

Build custom tools for your store

Join the SDK program to create useful ecommerce utilities for your store.