Heat Transfer Rate Calculator

Compute steady-state conduction through a plane slab with Fourier's law, from a tabulated conductivity, area, thickness and temperature difference.

Privacy First
0 Runs
Updated 2026-11-06
No upload
Runs in this tab
No signup

Fourier conduction through one slab

The page evaluates Q/t = k·A·ΔT/d. Pick a material for k in W/(m·K) — copper 401, aluminium 205, mild steel 50, stainless steel 16, concrete 1.7, soda-lime glass 1.05, brick 0.6, oak 0.17, still air 0.026 — then give the face area in m², the thickness in mm and the temperature difference in K. The answer is printed in watts with the substituted arithmetic and the heat flux in W/m².

This is steady state through a single plane slab, with the conductivity taken from standard tables near 300 K. It does not model surface films, radiation, a multilayer wall, thermal bridging or heat stored while the wall warms up, and a thickness of zero is refused because it divides by zero. It is an estimate, not a specification.

The arithmetic runs in this tab from four values you type. Nothing is uploaded, no assembly is stored, and the same numbers print the same rate.

Compute steady-state conduction through one plane slab with Fourier’s law, Q/t = k·A·ΔT/d, from a tabulated conductivity, the face area, the thickness and the temperature difference.

It is a single-slab estimate with table values: no surface films, no radiation, no multilayer wall, and a zero thickness is refused rather than clamped.

How to use Heat Transfer Rate Calculator

Set Face area (m²), pick a Material from the nine tabulated conductivities, and enter Temperature difference (°C).

Type Thickness (mm) — zero is refused rather than clamped — and press Run.

Read the heat transfer rate in watts, with the flux in W/m² on the line under it and the substitution printed alongside.

The substitution, printed

The answer prints Q/t with the numbers substituted, so the arithmetic can be checked without trusting the code: brick at k = 0.6 W/(m·K), 2 m² of face, 100 mm thick and 20 K of difference gives 0.6 × 2 × 20 / 0.1 = 240 W, and the flux is the same figure per square metre, 120 W/m².

The flux line is there because the rate scales with area: doubling the face doubles the watts and leaves the W/m² unchanged. That is the quantity a wall assembly is usually compared on, and it is the one figure here that does not depend on how much wall you have.

What to Expect

Best for

  • Checking a wall or a plate against a hand calculation.
  • Comparing two materials over the same thickness and temperature.

What this tool keeps

  • The arithmetic runs in this tab and the dimensions are never posted, so the page works offline and retains no assembly.

Sample input

Brick, 2 m², 100 mm, 20 °C

Sample output

Q/t = 240 W Q/t = k·A·ΔT/d = 0.6 × 2 × 20 / 0.1 m Through brick (k = 0.6 W/(m·K)), 100 mm thick; flux 120 W/m².

Frequently asked questions

Which formula does it use?

Fourier conduction through a plane slab: Q/t = k·A·ΔT/d, with k in W/(m·K) from a table, A the face area in m², ΔT in K and d the thickness in m.

Where do the conductivities come from?

Standard engineering tables near 300 K: copper 401, aluminium 205, mild steel 50, stainless steel 16, concrete 1.7, soda-lime glass 1.05, brick 0.6, oak 0.17, still air 0.026 W/(m·K). The page prints the value it used.

What does it not model?

Surface films, radiation, a multilayer wall, thermal bridging and the heat stored while the wall warms up. It is steady state through one slab, and a thickness of zero is refused because it divides by zero.